Issue StoriesNebulizers VS Inhalers: And the Winner Is?by John A. Wolfe, RRT For the past 3 decades, the marketplace has evolved to provide inhaled medications that are more effective and easier to use. Heightened awareness of environmental and infection-control concerns has spawned recommendations and regulations to address those issues. Inhalation provides an excellent delivery route for the treatment of both pulmonary and nonpulmonary conditions. Delivering medications via inhalation generally requires smaller doses, offers a rapid onset of drug action, and reduces systemic effects, compared with other routes of administration. Nebulizers, metered dose inhalers (MDIs), and dry powder inhalers (DPIs) have been competing in the marketplace for many years, and each has found a niche. While nebulizers have evolved relatively independently of the drug formulations that they deliver, MDIs and DPIs have necessarily been developed for their specific pharmaceuticals. Nebulizers are easy to use and adapt to a variety of challenges, making them a continued favorite in hospitals. The same nebulizer can be used to administer a variety of drugs, and can be adapted for use with a mouthpiece, adult or pediatric face mask, tracheostomy collar, T piece, or ventilator circuit. No matter which interface is in use, an RT will find a way to deliver aerosolized medications effectively via nebulizer. Inhalers suit active lifestyles in people living with chronic pulmonary conditions. A child with asthma can accompany his grandfather with chronic obstructive pulmonary disease on a fishing trip far from the nearest gas source or electrical outlet. They can be assured of getting effective doses of the appropriate drugs at the times and places that suit them. The marketplace has been quick to respond to changes in consumer needs, government regulations, and pharmaceuticals. Manufacturers of MDIs state that their products are as effective as nebulizers when properly used, while nebulizer manufacturers emphasize that MDIs are often used incorrectly. Advocates of both technologies suggest that their approaches are superior, both in particulate deposition and for cost savings.1-4 The efficacy of inhaled medications may be affected by the patients age, severity of disease, and inhalation technique, as well as the specific pharmacological properties of the drug. Oropharyngeal deposition is a consistent confounding factor that continues to challenge each delivery modality. Cost, convenience, and ease of use can all affect patient compliance. Nebulizer Characteristics Handheld ultrasonic nebulizers can produce a high output of particles in the therapeutic range of 1 to 5 mm.7 Although compact and lightweight, and allowing a variety of power sources, their relatively sophisticated design makes it hard for them to surpass compressor-driven nebulizers for long-term reliability. They have continued to evolve, becoming smaller, lighter, and somewhat less expensive. Not all medications are compatible with ultrasonic nebulizers. Budesonide and dornase alfa are not approved for use in ultrasonic nebulizers. The Joint Commission on Accreditation of Healthcare Organizations and the US Food and Drug Administration (FDA) have both issued strong recommendations to discontinue use of multidose bottled medications traditionally used in nebulizers and replace them with sterile, premixed, premeasured, unit-dose medications. There are three main reasons for this preference. First, benzalkonium chloride, an antibacterial agent added to some bottled medications as a preservative, can cause airway constriction, potentially blunting the effectiveness of the drugs. Second, bottled, multidose medications can be a source of nosocomial infections. Third, unit-dose medications eliminate possible dosing errors that are inherent in mixing each individual dose. It is inadvertently possible to administer a nebulizer treatment loaded only with diluents or containing a double dose of the medication. Replacing multidose medications with unit-dose medications has been endorsed by the Institute for Safe Medication Practices and the American Society of Health-System Pharmacists. Although cost differences in medication delivery via nebulizers vs MDIs continue to be debated, one key financial aspect for Medicare patients who take daily treatments at home gives nebulizers a clear advantage. Both nebulizers and the medications used in them are generally a covered Medicare expense. MDIs and DPIs are an out-of-pocket expense and can cost $100 per month or more. Consequently, some Medicare patients may be noncompliant or may ration their MDI doses. MDI Characteristics On June 11, 2004, Rau9 addressed the FDAs Pulmonary-Allergy Drugs Advisory Committee on behalf of the American Association for Respiratory Care (AARC). He stated, The AARC supports phasing out the use of CFC propellants for aerosolized inhaled medications, and in particular, the removal of the essential designation for CFC albuterol metered-dose inhalers.9 He pointed out that effective non-CFC alternatives are now readily available, while emphasizing the need to keep these new drugs competitively priced. Proper technique is essential for MDI effectiveness, and several studies10,11 have shown an alarming lack of ability by medical staff to instruct patients correctly in optimal technique. In one study, for example, only 5% used an MDI perfectly. This improved to 13% after a lecture and demonstration, and 73% after an intensive one-on-one session.8 Using MDIs with a holding chamber reduces the need for patient coordination while increasing delivery of medication to the airways and diminishing oropharyngeal deposition by 10 to 15 times. Due to the phaseout of CFC propellant inhalers and improvements in DPI engineering, their acceptance and use have increased exponentially. Prescriptions for salmeterol via DPI, for example, increased 250% in 3 years, compared with the MDI formulation.12 The ability of clinicians to instruct patients in proper technique has been challenging with DPIs, just as it has been with MDIs. A 1997 study13 showed that, when tested for MDI and DPI knowledge, RTs scored 67%, MDs scored 48%, and RNs scored 39%. When demonstrating use, RTs scored only 60% on a DPI and MDs scored 21%. The pharmaceutical industry has responded with improvements in DPI design, making the use of current products much easier for clinicians to demonstrate and for patients to perform. For example, early DPIs required the patient to load each dose into the holding chamber; more recent devices allow for a simplified dosage loading by just the turn of a dial or tube. As with MDIs, effective medication delivery using DPIs depends on the patients ability to generate sufficient inspiratory flow, and DPIs are not recommended for patients with acute bronchospasm or children under 6 years of age.7 The latest designs, however, are able to deliver therapeutic doses with much lower inspiratory flows than previous designs required.14 Conclusion John A. Wolfe, RRT, is a contributing writer to RT. References |
|
|
|
ADDITIONAL ONLINE RESOURCES |
|